Anti-static Floor Load Form

Jun. 15, 2019

Anti-static floor is not unfamiliar to many people. It is known to be used in special places such as data room, power dispatching room, data processing center, etc. Therefore, it is stricter in terms of anti-static performance, installation and so on. But many times, anti-static floor load is the most overlooked part of everyone, and many people are still unfamiliar with anti-static floor load. Today, the Aluminum Access Floor Pedestal Factory is here to talk to you about the anti-static floor load.

Load refers to the weight carried by building components in construction projects. Generally divided into three types: limit concentrated load, uniform load, rolling load. In the anti-static raised floor product report, it often appears, and many customers are unclear about the concept of several mechanical properties of the floor when reading the test report of the anti-static raised floor. Let's take a look at the anti-static with Raised Floor Pedestal Factory. Several common loads on raised floors.

1. Extreme concentrated load, concentrated load

The floor shall be installed according to the actual use. The surrounding supporting movable floor shall ensure that the four sides of the floor are installed on the beam; the four-corner floor type movable floor shall ensure that the four corners of the floor are installed on the support, and the support is adjusted to make the floor surface level ensure four support columns. At the same time stressed. Place the pressure sensor and rubber pad in the center of the floor. The pressure sensor and rubber pad are 50mm in diameter. Increase the pressure until the floor is broken. The load at this time is the limit concentrated load of the floor. The significance of the concentrated load is to indicate the point load under normal use of the floor. The value of the equipment that can be withstood by the floor can be calculated by this value (in the case of point load). The principle is the same as above. Under this load, the amount of deformation of the floor is less than 2 mm.


Calcium Sulphate Raised Access Floor


2. Uniform load

It refers to the force (load) evenly distributed on the floor structure. Under the uniform load, the load weight of each point of the Calcium Sulphate Raised Access Floor is equal. This parameter indicates the weight that the floor can withstand when the equipment is in contact with the floor. So its unit is N/m2. It calculates the weight of the equipment that can be carried under the contact of the floor with the equipment.

In summary, the limit concentrated load is a test quantity with strict measurement specifications and scientific observation values and is the value that best reflects the floor quality in the mechanical performance of the machine room floor. The uniform load is used to estimate the weight of the equipment that can be placed on the floor and is practical value.